{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2025-50121", "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "state": "PUBLISHED", "assignerShortName": "schneider", "dateReserved": "2025-06-12T13:53:23.602Z", "datePublished": "2025-07-11T09:14:55.415Z", "dateUpdated": "2025-11-03T20:05:35.286Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure™ IT Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "Prior to", "status": "affected", "version": "8.3", "versionType": "custom" } ] } ], "datePublic": "2025-07-08T05:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default." } ], "value": "A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "baseScore": 9.5, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider", "dateUpdated": "2025-07-13T23:28:32.348Z" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-189-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-07-11T15:09:11.955744Z", "id": "CVE-2025-50121", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-07-11T15:15:05.184Z" } }, { "title": "CVE Program Container", "references": [ { "url": "http://seclists.org/fulldisclosure/2025/Jul/6" } ], "providerMetadata": { "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2025-11-03T20:05:35.286Z" } } ] } }