{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-54459",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2025-10-08T22:13:45.410Z",
"datePublished": "2025-10-29T21:51:34.082Z",
"dateUpdated": "2025-10-30T20:31:36.976Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Hospital Manager Backend Services",
"vendor": "Vertikal Systems",
"versions": [
{
"lessThanOrEqual": "September 19, 2025",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vertikal_systems:hospital_manager_backend_services:*:*:*:*:*:*:*:*",
"versionEndIncluding": "september_19,_2025",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pundhapat Sichamnong reported these vulnerabilities to CISA."
}
],
"datePublic": "2025-10-28T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths."
}
],
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2025-10-29T21:51:34.082Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support for assistance.\n\n
"
}
],
"value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support https://www.vertikalsystems.com/en/products/pm/contact.php for assistance."
}
],
"source": {
"advisory": "ICSMA-25-301-01",
"discovery": "EXTERNAL"
},
"title": "Vertikal Systems Hospital Manager Backend Services Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-10-30T20:31:25.447134Z",
"id": "CVE-2025-54459",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-10-30T20:31:36.976Z"
}
}
]
}
}