{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2025-54459", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2025-10-08T22:13:45.410Z", "datePublished": "2025-10-29T21:51:34.082Z", "dateUpdated": "2025-10-30T20:31:36.976Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Hospital Manager Backend Services", "vendor": "Vertikal Systems", "versions": [ { "lessThanOrEqual": "September 19, 2025", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "cpeApplicability": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:vertikal_systems:hospital_manager_backend_services:*:*:*:*:*:*:*:*", "versionEndIncluding": "september_19,_2025", "versionStartIncluding": "0", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "OR" } ], "credits": [ { "lang": "en", "type": "finder", "value": "Pundhapat Sichamnong reported these vulnerabilities to CISA." } ], "datePublic": "2025-10-28T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths." } ], "value": "Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-497", "description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-10-29T21:51:34.082Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support for assistance.\n\n
" } ], "value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support https://www.vertikalsystems.com/en/products/pm/contact.php  for assistance." } ], "source": { "advisory": "ICSMA-25-301-01", "discovery": "EXTERNAL" }, "title": "Vertikal Systems Hospital Manager Backend Services Exposure of Sensitive System Information to an Unauthorized Control Sphere", "x_generator": { "engine": "Vulnogram 0.4.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2025-10-30T20:31:25.447134Z", "id": "CVE-2025-54459", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-10-30T20:31:36.976Z" } } ] } }