{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-6260", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2025-06-18T22:35:45.412Z", "datePublished": "2025-07-24T20:53:17.534Z", "dateUpdated": "2025-07-25T13:31:50.926Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "X-Series WiFi thermostats", "vendor": "Network Thermostat", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "v4.5", "versionType": "custom" }, { "lessThan": "v9.46", "status": "affected", "version": "v9.6", "versionType": "custom" }, { "lessThan": "v10.29", "status": "affected", "version": "v10.1", "versionType": "custom" }, { "lessThan": "v11.5", "status": "affected", "version": "v11.1", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Souvik Kandar reported this vulnerability to CISA." } ], "datePublic": "2025-07-24T16:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface." } ], "value": "The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-07-24T20:53:17.534Z" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-205-02" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
Network Thermostat recommends users to update to the following (or newer) versions:
This update was applied automatically to reachable units, requiring no action from end users.
If end users would like their units behind firewalls to be updated, contact Network Thermostat at support@networkthermostat.com to coordinate an update.
\n\n