{ "dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": { "cveId": "CVE-2025-9574", "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "state": "PUBLISHED", "assignerShortName": "ABB", "dateReserved": "2025-08-28T10:04:01.947Z", "datePublished": "2025-10-20T16:56:32.337Z", "dateUpdated": "2025-10-24T10:04:57.390Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ALS-mini-s4 IP", "vendor": "ABB", "versions": [ { "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ALS-mini-s8 IP", "vendor": "ABB", "versions": [ { "status": "affected", "version": "0" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "ABB acknowledges Souvik Kandar of MicroSec (microsec.io), for reporting vulnerabilities in responsible disclosure." } ], "datePublic": "2025-10-20T00:36:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.
This issue affects . \n\nAll firmware versions with the Serial Number from 2000 to 5166\n\n
" } ], "value": "Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects . \n\nAll firmware versions with the Serial Number from 2000 to 5166" } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "USER", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.9, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "RED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "DIFFUSE", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:H/S:N/AU:Y/R:U/V:D/RE:M/U:Red", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "MODERATE" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB", "dateUpdated": "2025-10-24T10:04:57.390Z" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=4TZ00000006007&LanguageCode=en&DocumentPartId=PDF&Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "Missing Authentication Vulnerability", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Workarounds are specific measures that a user can take to help block an attack. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can\nhelp block known attack vectors. When a workaround reduces functionality, this is identified below as\n“Impact of workaround”.