{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-102076", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2026-09-28T17:37:23.338Z", "datePublished": "2026-10-13T09:19:16.853Z", "dateUpdated": "2026-10-13T09:19:16.853Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2026-10-13T09:19:16.853Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate user-supplied input in upload code. This could allow an unauthenticated remote attacker to cause a denial of service." } ], "affected": [ { "vendor": "Siemens", "product": "APOGEE MBC (PPC) (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE MBC (PPC) (P2 Ethernet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE MEC (PPC) (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE MEC (PPC) (P2 Ethernet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Compact (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.7", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Compact (P2 Ethernet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2.8.21", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Modular (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.7", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "APOGEE PXC Modular (P2 Ethernet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2.8.21", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "TALON TC Compact (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.7", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "TALON TC Modular (BACnet)", "versions": [ { "status": "affected", "version": "0", "lessThan": "V3.5.7", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH" } }, { "cvssV4_0": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "baseScore": 8.7, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-333035.html" } ] } } }