{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-105484", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2026-10-05T15:01:47.713Z", "datePublished": "2026-10-06T01:00:19.684Z", "dateUpdated": "2026-10-06T13:25:02.411Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2026-10-06T01:00:19.684Z" }, "title": "TOTOLINK X6000R UploadFirmwareFile cstecgi.cgi firmware_check os command injection", "problemTypes": [ { "descriptions": [ { "type": "CWE", "cweId": "CWE-78", "lang": "en", "description": "OS Command Injection" } ] }, { "descriptions": [ { "type": "CWE", "cweId": "CWE-77", "lang": "en", "description": "Command Injection" } ] } ], "affected": [ { "vendor": "TOTOLINK", "product": "X6000R", "versions": [ { "version": "9.4.0cu.652_B20230116", "status": "affected" } ], "cpes": [ "cpe:2.3:o:totolink:x6000r_firmware:*:*:*:*:*:*:*:*" ], "modules": [ "UploadFirmwareFile Handler" ] } ], "descriptions": [ { "lang": "en", "value": "A security vulnerability has been detected in TOTOLINK X6000R 9.4.0cu.652_B20230116. The impacted element is the function firmware_check of the file /cgi-bin/cstecgi.cgi of the component UploadFirmwareFile Handler. Such manipulation of the argument file_name leads to os command injection. The attack may be performed from remote." } ], "metrics": [ { "cvssV4_0": { "version": "4.0", "baseScore": 10, "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X", "baseSeverity": "CRITICAL" } }, { "cvssV3_1": { "version": "3.1", "baseScore": 10, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R", "baseSeverity": "CRITICAL" } }, { "cvssV3_0": { "version": "3.0", "baseScore": 10, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R", "baseSeverity": "CRITICAL" } }, { "cvssV2_0": { "version": "2.0", "baseScore": 10, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR" } } ], "timeline": [ { "time": "2026-10-05T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed" }, { "time": "2026-10-05T02:00:00.000Z", "lang": "en", "value": "VulDB entry created" }, { "time": "2026-10-05T17:07:07.000Z", "lang": "en", "value": "VulDB entry last update" } ], "credits": [ { "lang": "en", "value": "liumingjie (VulDB User)", "type": "reporter" }, { "lang": "en", "value": "VulDB Vulnerability Moderation Team", "type": "coordinator" } ], "references": [ { "url": "https://vuldb.com/vuln/413619", "name": "VDB-413619 | TOTOLINK X6000R UploadFirmwareFile cstecgi.cgi firmware_check os command injection", "tags": [ "vdb-entry", "technical-description" ] }, { "url": "https://vuldb.com/vuln/413619/cti", "name": "VDB-413619 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ] }, { "url": "https://vuldb.com/cve/CVE-2026-105484", "name": "CVE-2026-105484 | CVE Analysis and Report", "tags": [ "third-party-advisory" ] }, { "url": "https://vuldb.com/submit/984434", "name": "Submit #984434 | TOTOLINK X6000R 9.4.0cu.652_B20230116 CWE-78 OS Command Injection", "tags": [ "third-party-advisory" ] }, { "url": "https://www.totolink.net/", "tags": [ "broken-link", "product" ] } ], "x_generator": [ "VulDB PVTS v202610" ] }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2026-10-06T13:24:46.638835Z", "id": "CVE-2026-105484", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-10-06T13:25:02.411Z" } } ] } }