{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-107615", "assignerOrgId": "33c584b5-0579-4c06-b2a0-8d8329fcab9c", "state": "PUBLISHED", "assignerShortName": "securin", "dateReserved": "2026-10-08T13:23:07.677Z", "datePublished": "2026-10-08T13:39:59.358Z", "dateUpdated": "2026-10-08T14:00:27.042Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "33c584b5-0579-4c06-b2a0-8d8329fcab9c", "shortName": "securin", "dateUpdated": "2026-10-08T13:39:59.358Z" }, "title": "DLL search order hijacking via screenhooks libraries in TightVNC Server", "descriptions": [ { "lang": "en", "value": "An uncontrolled search path element vulnerability in GlavSoft TightVNC Server for Windows before 2.8.88 allows a local authenticated user to execute arbitrary code with SYSTEM privileges. DynamicLibrary::init() (and ThemeLib) load screenhooks32.dll / screenhooks64.dll with LoadLibrary() using a bare file name and no LOAD_LIBRARY_SEARCH_* flags, so the TightVNC service follows the default DLL search order and loads an attacker-planted DLL from a writable directory earlier in that order (for example, an installation directory with permissive ACLs)." } ], "affected": [ { "vendor": "GlavSoft", "product": "TightVNC", "platforms": [ "Windows" ], "modules": [ "TightVNC Server (screen hooks loader)" ], "programFiles": [ "DynamicLibrary.cpp", "ThemeLib.cpp" ], "programRoutines": [ { "name": "DynamicLibrary::init()" } ], "defaultStatus": "unaffected", "versions": [ { "version": "0", "lessThan": "2.8.88", "status": "affected", "versionType": "custom" } ] } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "type": "CWE", "cweId": "CWE-427", "description": "CWE-427 Uncontrolled Search Path Element" } ] } ], "metrics": [ { "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ], "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH" } } ], "solutions": [ { "lang": "en", "value": "Upgrade TightVNC for Windows to version 2.8.88 or later." } ], "references": [ { "url": "https://sourceforge.net/p/vnc-tight/bugs/1666/", "name": "TightVNC bug #1666", "tags": [ "issue-tracking" ] }, { "url": "https://www.tightvnc.com/whatsnew.php", "name": "TightVNC release notes (2.8.88)", "tags": [ "release-notes", "patch" ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Arjun Basnet from Securin" } ], "timeline": [ { "time": "2026-05-30T00:00:00.000Z", "lang": "en", "value": "Reported to GlavSoft" }, { "time": "2026-06-02T00:00:00.000Z", "lang": "en", "value": "Vendor acknowledged" }, { "time": "2026-06-19T00:00:00.000Z", "lang": "en", "value": "TightVNC 2.8.88 released with fix" } ], "source": { "discovery": "EXTERNAL" }, "impacts": [ { "capecId": "CAPEC-471", "descriptions": [ { "lang": "en", "value": "CAPEC-471 Search Order Hijacking" } ] } ], "workarounds": [ { "lang": "en", "value": "Ensure the TightVNC installation directory and every directory on the system PATH are writable only by administrators." } ] }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2026-10-08T14:00:03.531511Z", "id": "CVE-2026-107615", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-10-08T14:00:27.042Z" } } ] } }