{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-118462", "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158", "state": "PUBLISHED", "assignerShortName": "ENISA", "dateReserved": "2026-10-28T08:46:25.411Z", "datePublished": "2026-11-09T11:51:58.643Z", "dateUpdated": "2026-11-09T11:51:58.643Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158", "shortName": "ENISA", "dateUpdated": "2026-11-09T11:51:58.643Z" }, "title": "AIS update mechanism executes unverified code", "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-494", "description": "CWE-494", "type": "CWE" } ] } ], "affected": [ { "vendor": "CompuGroup Medical", "product": "Infantia", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "1.3.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.files.delivery" }, { "vendor": "CompuGroup Medical", "product": "Profim", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "1.3.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.files.delivery" }, { "vendor": "CompuGroup Medical", "product": "Venere", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "1.3.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.files.delivery" }, { "vendor": "CompuGroup Medical", "product": "Phronesis", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "1.3.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.files.delivery" }, { "vendor": "CompuGroup Medical", "product": "Infantia", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "2.12.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.liveupdates" }, { "vendor": "CompuGroup Medical", "product": "Profim", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "2.12.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.liveupdates" }, { "vendor": "CompuGroup Medical", "product": "Venere", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "2.12.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.liveupdates" }, { "vendor": "CompuGroup Medical", "product": "Phronesis", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "2.12.0", "versionType": "semver" } ], "defaultStatus": "unknown", "packageName": "cgm.liveupdates" } ], "descriptions": [ { "lang": "en", "value": "Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution.", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution." } ] } ], "references": [ { "url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical" }, { "url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html" } ], "metrics": [ { "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ], "cvssV4_0": { "attackVector": "NETWORK", "attackComplexity": "HIGH", "attackRequirements": "PRESENT", "privilegesRequired": "NONE", "userInteraction": "NONE", "vulnConfidentialityImpact": "HIGH", "subConfidentialityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "subIntegrityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "version": "4.0", "baseSeverity": "CRITICAL", "baseScore": 9.2, "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N" } } ], "credits": [ { "lang": "en", "value": "Marco Sala", "type": "finder" }, { "lang": "en", "value": "CSIRT-IT", "type": "coordinator" }, { "lang": "en", "value": "ApoCert srl", "type": "finder" } ], "x_generator": { "engine": "Vulnogram 1.0.5" }, "source": { "discovery": "UNKNOWN" } } } }