{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-124281", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "state": "PUBLISHED", "assignerShortName": "icscert", "dateReserved": "2026-11-10T20:46:50.517Z", "datePublished": "2026-11-20T18:51:15.505Z", "dateUpdated": "2026-11-20T19:01:03.114Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2026-11-20T18:51:15.505Z" }, "title": "Elecbrakes Exposed Dangerous Method or Function", "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-749", "description": "CWE-749", "type": "CWE" } ] } ], "affected": [ { "vendor": "Elecbrakes", "product": "EB2", "versions": [ { "status": "affected", "version": "0", "lessThanOrEqual": "3.0.4.2.0", "versionType": "custom" }, { "status": "unaffected", "version": "EB2 3.0.4.4.3" } ], "defaultStatus": "unaffected" }, { "vendor": "Elecbrakes", "product": "ELBC2000", "versions": [ { "status": "affected", "version": "All versions" } ], "defaultStatus": "affected" }, { "vendor": "Elecbrakes", "product": "VM1", "versions": [ { "status": "affected", "version": "0", "lessThan": "1.3.4.2.1", "versionType": "custom" }, { "status": "unaffected", "version": "VM1 1.3.4.2.1" } ], "defaultStatus": "unaffected" } ], "descriptions": [ { "lang": "en", "value": "The affected products use an unprotected firmware-update channel, which may allow for unauthorized firmware modification.", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "The affected products use an unprotected firmware-update channel, which may allow for unauthorized firmware modification." } ] } ], "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-323-02" }, { "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-323-02.json" } ], "metrics": [ { "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ], "cvssV3_1": { "version": "3.1", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "availabilityImpact": "LOW", "baseSeverity": "MEDIUM", "baseScore": 6.1, "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:L" } }, { "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ], "cvssV4_0": { "attackVector": "ADJACENT", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "NONE", "vulnConfidentialityImpact": "NONE", "subConfidentialityImpact": "NONE", "vulnIntegrityImpact": "LOW", "subIntegrityImpact": "LOW", "vulnAvailabilityImpact": "LOW", "subAvailabilityImpact": "LOW", "exploitMaturity": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "version": "4.0", "baseSeverity": "MEDIUM", "baseScore": 5.3, "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:L/SA:L" } } ], "workarounds": [ { "lang": "en", "value": "Elecbrakes ELBC2000\nis the predecessor to the EB2 and the VM1 and is no longer sold. The vendor is determining how to address these vulnerabilities for this particular controller.", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "Elecbrakes ELBC2000\nis the predecessor to the EB2 and the VM1 and is no longer sold. The vendor is determining how to address these vulnerabilities for this particular controller." } ] } ], "solutions": [ { "lang": "en", "value": "Elecbrakes EB2: Elecbrakes has released updated firmware (EB2 3.0.4.4.3). Users should open the Elecbrakes app and install the firmware update.", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "