"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-12819",
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"state": "PUBLISHED",
"assignerShortName": "Deltaww",
"dateReserved": "2026-06-21T10:18:28.804Z",
"datePublished": "2026-06-30T06:28:51.514Z",
"dateUpdated": "2026-06-30T12:50:59.070Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww",
"dateUpdated": "2026-06-30T06:28:51.514Z"
},
"title": "DVP-12SE Missing Authentication and Unauthorized Write access Vulnerability",
"datePublic": "2026-06-30T05:29:00.000Z",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"type": "CWE"
}
]
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115: Authentication Bypass"
}
]
}
],
"affected": [
{
"vendor": "deltaww",
"product": "DVP-12SE",
"versions": [
{
"status": "affected",
"version": "*"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:deltaww:dvp-12se:*:*:*:*:*:*:*:*"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions."
}
]
}
],
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00011_DVP12SE%20Multiple%20Vulnerabilities%20(CVE-2026-12818,%20CVE-2026-12819)_v1.0.pdf"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "CRITICAL",
"baseScore": 9.3,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"workarounds": [
{
"lang": "en",
"value": "Users are recommended to take the following mitigation measures:\n\n * Enable the IP Filter feature: Configure and enable the PLC's built-in IP Filter function via the programming software. Restrict access exclusively to the IP addresses of trusted devices (such as designated HMI panels or SCADA hosts) to block unauthorized network access.\n\n * Set up PLC password protection: Enable password protection for the PLC within the programming software to ensure the device's core control logic and parameters cannot be easily downloaded, overwritten, or tampered with.\n\n * Implement network isolation and firewall protection: Deploy the PLC within an independent local area network (OT control network) secured by a firewall. Never connect the device directly to the office network or the Internet. If remote access is required, enforce the use of a secure, authorized VPN tunnel.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Users are recommended to take the following mitigation measures:\n