{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-138102", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2026-11-27T20:47:33.105Z", "datePublished": "2026-11-29T01:30:33.103Z", "dateUpdated": "2026-11-29T01:30:33.103Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2026-11-29T01:30:33.103Z" }, "title": "D-Link DIR-620S Diagnostic anweb os command injection", "problemTypes": [ { "descriptions": [ { "type": "CWE", "cweId": "CWE-78", "lang": "en", "description": "OS Command Injection" } ] }, { "descriptions": [ { "type": "CWE", "cweId": "CWE-77", "lang": "en", "description": "Command Injection" } ] } ], "affected": [ { "vendor": "D-Link", "product": "DIR-620S", "versions": [ { "version": "4.0.2", "status": "affected" } ], "cpes": [ "cpe:2.3:h:d-link:dir-620s:*:*:*:*:*:*:*:*" ], "modules": [ "Diagnostic Handler" ] } ], "descriptions": [ { "lang": "en", "value": "A security vulnerability has been detected in D-Link DIR-620S 4.0.2. This vulnerability affects unknown code of the file /usr/sbin/anweb of the component Diagnostic Handler. The manipulation of the argument I leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used." } ], "metrics": [ { "cvssV4_0": { "version": "4.0", "baseScore": 9.4, "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P", "baseSeverity": "CRITICAL" } }, { "cvssV3_1": { "version": "3.1", "baseScore": 9.9, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R", "baseSeverity": "CRITICAL" } }, { "cvssV3_0": { "version": "3.0", "baseScore": 9.9, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R", "baseSeverity": "CRITICAL" } }, { "cvssV2_0": { "version": "2.0", "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR" } } ], "timeline": [ { "time": "2026-11-27T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed" }, { "time": "2026-11-27T01:00:00.000Z", "lang": "en", "value": "VulDB entry created" }, { "time": "2026-11-28T03:16:46.000Z", "lang": "en", "value": "VulDB entry last update" } ], "credits": [ { "lang": "en", "value": "MadLies", "type": "finder" }, { "lang": "en", "value": "MadLies (VulDB User)", "type": "reporter" }, { "lang": "en", "value": "MadLies (VulDB User)", "type": "analyst" } ], "references": [ { "url": "https://vuldb.com/vuln/445020", "name": "VDB-445020 | D-Link DIR-620S Diagnostic anweb os command injection", "tags": [ "vdb-entry", "technical-description" ] }, { "url": "https://vuldb.com/vuln/445020/cti", "name": "VDB-445020 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ] }, { "url": "https://vuldb.com/cve/CVE-2026-138102", "name": "CVE-2026-138102 | CVE Analysis and Report", "tags": [ "third-party-advisory" ] }, { "url": "https://vuldb.com/submit/1073265", "name": "Submit #1073265 | D-Link DIR-620S 4.0.2 OS Command Injection", "tags": [ "third-party-advisory" ] }, { "url": "https://github.com/MadLies/dlink-dir620s-anweb-cmdinjection", "tags": [ "exploit" ] }, { "url": "https://www.dlink.com/", "tags": [ "product" ] } ], "x_generator": [ "VulDB PVTS v202611" ] } } }