{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-17091", "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522", "state": "PUBLISHED", "assignerShortName": "ibm", "dateReserved": "2026-07-24T14:46:42.523Z", "datePublished": "2026-08-19T19:45:15.751Z", "dateUpdated": "2026-08-20T15:57:04.808Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522", "shortName": "ibm", "dateUpdated": "2026-08-19T19:45:15.751Z" }, "title": "Power System Integer Overflow", "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-190", "description": "CWE-190 Integer Overflow or Wraparound", "type": "CWE" } ] } ], "affected": [ { "vendor": "IBM", "product": "PowerVM Hypervisor", "versions": [ { "status": "affected", "version": "FW1120.00" }, { "status": "affected", "version": "FW1110.00", "lessThanOrEqual": "FW1110.30", "versionType": "semver" }, { "status": "affected", "version": "FW1060.00", "lessThanOrEqual": "FW1060.80", "versionType": "semver" }, { "status": "affected", "version": "FW950.00", "lessThanOrEqual": "FW950.H2", "versionType": "semver" } ], "cpes": [ "cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*", "cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*", "cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*", "cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*", "cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*", "cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*", "cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*" ] } ], "descriptions": [ { "lang": "en", "value": "IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call to inject an arbitrary amount of data into hypervisor or partition memory, resulting in either a crash causing a full platform re-IPL and terminating all hosted partitions, or corruption of hypervisor or partition memory. The PowerVM hypervisor will restart automatically; however, repeated exploitation could result in a sustained availability impact. Successful exploitation results in an integrity and availability impact to the managed system.", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "

IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call to inject an arbitrary amount of data into hypervisor or partition memory, resulting in either a crash causing a full platform re-IPL and terminating all hosted partitions, or corruption of hypervisor or partition memory. The PowerVM hypervisor will restart automatically; however, repeated exploitation could result in a sustained availability impact. Successful exploitation results in an integrity and availability impact to the managed system.

" } ] } ], "references": [ { "url": "https://www.ibm.com/support/pages/node/7283229", "tags": [ "vendor-advisory", "patch" ] } ], "metrics": [ { "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ], "cvssV3_1": { "version": "3.1", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseSeverity": "HIGH", "baseScore": 8.4, "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H" } } ], "solutions": [ { "lang": "en", "value": "Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System S1122 (9824-22A)\n * IBM Power System S1124 (9824-42A)\n * IBM Power System S1122s (9824-22B)\n * IBM Power System S1114 (9824-41B)\n * IBM Power System L1122 (9856-22H)\n * IBM Power System L1124 (9856-42H)\n * IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n * IBM Power System S1112 (9242-21B, 9242-21T)\n\n\n\nCustomers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System E1080 (9080-HEX)\n\n\nCustomers with the products below should installĀ  FW1060.81(1060_191), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System S1022 (9105-22A)\n * IBM Power System S1024 (9105-42A)\n * IBM Power System S1022s (9105-22B)\n * IBM Power System S1014 (9105-41B)\n * IBM Power System L1022 (9786-22H)\n * IBM Power System L1024 (9786-42H)\n * IBM Power System E1050 (9043-MRX)\n * IBM Power System S1012 (9028-21B)\n\n\n\n\n\n\nCustomers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.\nPower 9\n\n * IBM Power System S922 (9009-22G)\n * IBM Power System H922 (9223-22S)\n * IBM Power System S914 (9009-41G)\n * IBM Power System S924 (9009-42G)\n * IBM Power System H924 (9223-42S)\n * IBM Power System E950 (9040-MR9)\n * IBM Power System E980 (9080-M9S)\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/", "supportingMedia": [ { "type": "text/html", "base64": false, "value": "

Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.
Power 11

  1. IBM Power System E1180 (9080-HEU)

Customers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.
Power 11

  1. IBM Power System S1122 (9824-22A)
  2. IBM Power System S1124 (9824-42A)
  3. IBM Power System S1122s (9824-22B)
  4. IBM Power System S1114 (9824-41B)
  5. IBM Power System L1122 (9856-22H)
  6. IBM Power System L1124 (9856-42H)
  7. IBM Power System E1150 (9043-MRU)

Customers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.

Power 11

  1. IBM Power System S1112 (9242-21B, 9242-21T)


Customers with the products below should install FW1060.81(1060_184), or newer to remediate this vulnerability.
Power 10

  1. IBM Power System E1080 (9080-HEX)

Customers with the products below should installĀ  FW1060.81(1060_191), or newer to remediate this vulnerability.
Power 10

  1. IBM Power System S1022 (9105-22A)
  2. IBM Power System S1024 (9105-42A)
  3. IBM Power System S1022s (9105-22B)
  4. IBM Power System S1014 (9105-41B)
  5. IBM Power System L1022 (9786-22H)
  6. IBM Power System L1024 (9786-42H)
  7. IBM Power System E1050 (9043-MRX)
  8. IBM Power System S1012 (9028-21B)

Customers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability.
Power 9

  1. IBM Power System S922 (9009-22G)
  2. IBM Power System H922 (9223-22S)
  3. IBM Power System S914 (9009-41G)
  4. IBM Power System S924 (9009-42G)
  5. IBM Power System H924 (9223-42S)
  6. IBM Power System E950 (9040-MR9)
  7. IBM Power System E980 (9080-M9S)

The images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/

" } ] } ] }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "id": "CVE-2026-17091", "role": "CISA Coordinator", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "version": "2.0.3", "timestamp": "2026-08-20T15:46:20.531749Z" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-08-20T15:57:04.808Z" } } ] } }