{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-24437", "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "state": "PUBLISHED", "assignerShortName": "VulnCheck", "dateReserved": "2026-01-22T20:23:19.803Z", "datePublished": "2026-01-26T17:40:22.992Z", "dateUpdated": "2026-05-14T02:09:37.968Z" }, "containers": { "cna": { "affected": [ { "defaultStatus": "unknown", "product": "W30E V2", "vendor": "Shenzhen Tenda Technology Co., Ltd.", "versions": [ { "lessThanOrEqual": "16.01.0.19(5037)", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "cpeApplicability": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:tenda:w30e_firmware:*:*:*:*:*:*:*:*", "versionEndIncluding": "16.01.0.19(5037)" } ] } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Kazuma Matsumoto, a security researcher at GMO Cybersecurity by IERAE, Inc." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access." } ], "value": "Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 4.8, "baseSeverity": "MEDIUM", "exploitMaturity": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-525", "description": "CWE-525 Use of Web Browser Cache Containing Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "shortName": "VulnCheck", "dateUpdated": "2026-05-14T02:09:37.968Z" }, "references": [ { "tags": [ "product" ], "url": "https://www.tendacn.com/product/W30E" }, { "tags": [ "third-party-advisory" ], "url": "https://www.vulncheck.com/advisories/tenda-w30e-v2-missing-cache-controls-for-credential-bearing-pages" } ], "source": { "discovery": "UNKNOWN" }, "title": "Tenda W30E V2 Missing Cache Controls for Credential-bearing Pages", "x_generator": { "engine": "Vulnogram 0.5.0" } }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2026-01-26T21:06:40.408833Z", "id": "CVE-2026-24437", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-01-26T21:06:52.660Z" } } ] } }