{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-33862", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2026-03-24T12:34:25.562Z", "datePublished": "2026-05-12T08:21:14.646Z", "dateUpdated": "2026-05-13T01:48:31.646Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2026-05-12T08:21:14.646Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page." } ], "affected": [ { "vendor": "Siemens", "product": "Teamcenter V2312", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2312.0014", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Teamcenter V2406", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2406.0012", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Teamcenter V2412", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2412.0009", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Teamcenter V2506", "versions": [ { "status": "affected", "version": "0", "lessThan": "V2506.0005", "versionType": "custom" } ], "defaultStatus": "unknown" }, { "vendor": "Siemens", "product": "Teamcenter V2512", "versions": [ { "status": "unaffected", "version": "0", "lessThan": "*", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N", "baseScore": 7.3, "baseSeverity": "HIGH" } }, { "cvssV4_0": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N", "baseScore": 8.5, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html" } ] }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2026-05-13T01:41:31.594862Z", "id": "CVE-2026-33862", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-05-13T01:48:31.646Z" } } ] } }