{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-76542", "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "state": "PUBLISHED", "assignerShortName": "cisco", "dateReserved": "2026-08-19T12:02:03.644Z", "datePublished": "2026-11-19T19:55:26.918Z", "dateUpdated": "2026-11-19T20:40:03.541Z" }, "containers": { "cna": { "affected": [ { "product": "Splunk Enterprise", "vendor": "Splunk", "versions": [ { "version": "10.4", "status": "affected", "versionType": "custom", "lessThan": "10.4.5" }, { "version": "10.2", "status": "affected", "versionType": "custom", "lessThan": "10.2.9" }, { "version": "10.0", "status": "affected", "versionType": "custom", "lessThan": "10.0.12" }, { "version": "9.4", "status": "affected", "versionType": "custom", "lessThan": "9.4.17" } ], "modules": [ "Splunk Web" ] } ], "descriptions": [ { "lang": "en", "value": "In Splunk Enterprise versions below 10.4.5, 10.2.9, 10.0.12, and 9.4.17, an unauthenticated user could trick a user who has an active Splunk Web session into selecting the Top values by time field report on the Search page. The selection could run arbitrary Search Processing Language (SPL) searches and potentially expose stored credentials and indexed data.\nThe vulnerability is possible because Splunk Web does not correctly neutralize user-controlled data when it generates an SPL search for a field report.\nThe vulnerability requires the attacker to phish the user by tricking them into opening a link that the attacker creates. The unauthenticated user should not be able to exploit the vulnerability at will." } ], "references": [ { "url": "https://advisory.splunk.com/advisories/SVD-2026-1103" } ], "title": "SPL Injection through Splunk Web Field Reports in Splunk Enterprise", "datePublic": "2026-11-18T00:00:00.000Z", "problemTypes": [ { "descriptions": [ { "lang": "en", "type": "cwe", "cweId": "CWE-943", "description": "The application generates a query intended to access or manipulate data in a data store such as a database, but it does not neutralize or incorrectly neutralizes special elements that can modify the intended logic of the query." } ] } ], "source": { "advisory": "SVD-2026-1103", "discovery": "" }, "providerMetadata": { "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco", "dateUpdated": "2026-11-19T19:55:26.918Z" }, "metrics": [ { "cvssV3_1": { "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:N", "version": "3.1", "baseScore": 5.9, "baseSeverity": "MEDIUM" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "solutions": [ { "lang": "en", "value": "Upgrade Splunk Enterprise versions 10.6.1, 10.4.5, 10.2.9, 10.0.12, and 9.4.17 or higher." } ], "workarounds": [ { "lang": "en", "value": "The vulnerability affects instances with Splunk Web turned on. Turning Splunk Web off is a possible workaround.\nSee [Disable unnecessary Splunk Enterprise components](https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.2/install-splunk-enterprise-securely/disable-unnecessary-splunk-enterprise-components) and the [web.conf](https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.2/configuration-file-reference/10.2.0-configuration-file-reference/web.conf) configuration specification file for more information on turning off Splunk Web." } ] }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2026-11-19T20:26:47.130232Z", "id": "CVE-2026-76542", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-11-19T20:40:03.541Z" } } ] } }