{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-78556", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2026-08-24T19:48:32.550Z", "datePublished": "2026-10-13T09:18:55.291Z", "dateUpdated": "2026-10-13T09:18:55.291Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2026-10-13T09:18:55.291Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The affected software does not properly validate the server certificate when initiating a TLS connection. This allows an attacker to intercept and relay communication (Man-in-the-Middle attack) and to spoof a trusted entity by interfering in the communication path between the client and the intended server." } ], "affected": [ { "vendor": "Siemens", "product": "Industrial Edge App Publisher", "versions": [ { "status": "affected", "version": "0", "lessThan": "V1.27.9", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "baseScore": 7.4, "baseSeverity": "HIGH" } }, { "cvssV4_0": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N", "baseScore": 7.6, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-295", "description": "CWE-295: Improper Certificate Validation", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-968435.html" } ] } } }