{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-89196", "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "state": "PUBLISHED", "assignerShortName": "siemens", "dateReserved": "2026-09-11T07:45:20.918Z", "datePublished": "2026-10-13T09:18:59.688Z", "dateUpdated": "2026-10-13T09:18:59.688Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens", "dateUpdated": "2026-10-13T09:18:59.688Z" }, "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in facility names processed during the Bulk Import/Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database." } ], "affected": [ { "vendor": "Siemens", "product": "RUGGEDCOM CROSSBOW", "versions": [ { "status": "affected", "version": "0", "lessThan": "V6.0", "versionType": "custom" } ], "defaultStatus": "unknown" } ], "metrics": [ { "cvssV3_1": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 8.8, "baseSeverity": "HIGH" } }, { "cvssV4_0": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "baseScore": 8.7, "baseSeverity": "HIGH" } } ], "problemTypes": [ { "descriptions": [ { "lang": "en", "cweId": "CWE-89", "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')", "type": "CWE" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html" } ] } } }