{ "dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": { "cveId": "CVE-2026-9395", "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "state": "PUBLISHED", "assignerShortName": "VulDB", "dateReserved": "2026-05-24T06:18:55.457Z", "datePublished": "2026-05-24T20:00:11.355Z", "dateUpdated": "2026-05-26T13:20:38.881Z" }, "containers": { "cna": { "providerMetadata": { "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB", "dateUpdated": "2026-05-24T20:00:11.355Z" }, "title": "Besen BS20 EV Charging Station BLE/UDP insufficiently protected credentials", "problemTypes": [ { "descriptions": [ { "type": "CWE", "cweId": "CWE-522", "lang": "en", "description": "Insufficiently Protected Credentials" } ] } ], "affected": [ { "vendor": "Besen", "product": "BS20 EV Charging Station", "versions": [ { "version": "20260426", "status": "affected" } ], "cpes": [ "cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*" ], "modules": [ "BLE/UDP" ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was identified in Besen BS20 EV Charging Station up to 20260426. Affected is an unknown function of the component BLE/UDP. The manipulation leads to insufficiently protected credentials. The attack needs to be initiated within the local network. The original disclosure mentions, that \"[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026.\"" } ], "metrics": [ { "cvssV4_0": { "version": "4.0", "baseScore": 5.1, "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P", "baseSeverity": "MEDIUM" } }, { "cvssV3_1": { "version": "3.1", "baseScore": 3.5, "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R", "baseSeverity": "LOW" } }, { "cvssV3_0": { "version": "3.0", "baseScore": 3.5, "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R", "baseSeverity": "LOW" } }, { "cvssV2_0": { "version": "2.0", "baseScore": 2.7, "vectorString": "AV:A/AC:L/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR" } } ], "timeline": [ { "time": "2026-05-24T00:00:00.000Z", "lang": "en", "value": "Advisory disclosed" }, { "time": "2026-05-24T02:00:00.000Z", "lang": "en", "value": "VulDB entry created" }, { "time": "2026-05-24T08:24:12.000Z", "lang": "en", "value": "VulDB entry last update" } ], "credits": [ { "lang": "en", "value": "carfeii (VulDB User)", "type": "reporter" }, { "lang": "en", "value": "VulDB CNA Team", "type": "coordinator" } ], "references": [ { "url": "https://vuldb.com/vuln/365376", "name": "VDB-365376 | Besen BS20 EV Charging Station BLE/UDP insufficiently protected credentials", "tags": [ "vdb-entry" ] }, { "url": "https://vuldb.com/vuln/365376/cti", "name": "VDB-365376 | CTI Indicators (IOB, IOC, TTP)", "tags": [ "signature", "permissions-required" ] }, { "url": "https://vuldb.com/submit/813572", "name": "Submit #813572 | Besen EV Charging Station BS20 EV Charger Insufficiently Protected Credentials", "tags": [ "third-party-advisory" ] }, { "url": "https://github.com/carfeii/besen#finding-2-cleartext-credential-exposure-via-ble-and-udp-in-besen-home-ev-charging-station", "tags": [ "related" ] } ] }, "adp": [ { "metrics": [ { "other": { "type": "ssvc", "content": { "timestamp": "2026-05-26T13:20:04.970912Z", "id": "CVE-2026-9395", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "version": "2.0.3" } } } ], "title": "CISA ADP Vulnrichment", "providerMetadata": { "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-05-26T13:20:38.881Z" } } ] } }