{ "data": { "metadata": { "content_type": "application/vnd.ms-excel", "extension": ".xls", "file_name": "DD-F41.xls", "mime_type": "application/vnd.ms-excel", "reader": "OldExcelReader", "uploaded": "2023-08-09T08:02:12.704186" }, "tables": [ { "columns": [], "header": [ "Filename\tDD-F41", "Instrument name\t5500-0290 (192.168.1.99)", "Operator\t", "rundate\t28.06.2023", "Sample name\tDD-F41", "proceduresegments\tSelect Gas: Gas 1 ; Equilibrate 30.00 °C; Isothermal 3.0 min; Ramp 10.00 °C/min to 750.00 °C; Isothermal 5.0 min; Select Gas: Gas 2 ; Isothermal 10.0 min", "[File Parameters]\t", "Run date\t28.06.2023 14:37:28", "Trios version\t5.0.0.44608", "Original File Name\t", "Current File Name\tC:\\Users\\ITCP-AKT.ITCP-AKT-003\\Documents\\DD-F41.tri", "[Procedure]\t", "Procedure Name\tDD Standard 800 °C", "Sample Name\tDD-F41", "Pan Number\t2.0", "Sample Mass\t9.960 mg", "Pan Type\tPlatinum HT", "Comments\t", "Project Name\t", "Operator\t", "Test\tCustom", "Skip Weight Stabilization\t1", "Sample mass pre-weigh\tNot Available", "Stop on Gas Flow Error\tYes", "[Signal List]\t", "Signal #1\tTime (min)", "Signal #2\tTemperature (°C)", "Signal #3\tWeight (µg)", "Signal #4\tTemperature Difference (°C)", "Signal #5\tSample Purge (mL/min)", "Signal #6\tBalance Purge (mL/min)", "Signal #7\tSet Point Temperature (°C)", "Signal #8\tPower Delivered (W)", "Signal #9\tRamp Rate (°C/min)", "[Configuration]\t", "Company Name\tKIT", "Instrument Name\t5500-0290", "Instrument Type\tTGA5500", "Serial Number\t5500-0290", "IP\t192.168.1.99", "Location of Instrument\tManufacturing Test", "DisplayType\tTianmaV2", "Sampling Rate\t0.1", "Gas 1\tNitrogen", "Gas 2\tAir", "Selected Gas Channel\t1.0", "MTGA HiRes Licensed\tYes", "[Versions]\t", "Common IDD Version\t1.0", "Cortex Version\tVER 2.1.2.69", "Driver\t5.0.0.7", "GDM Version\t1.2.1.2", "TouchscreenVersion\t1.0.0.14551", "PCU Version\t1.2.0.22", "Transducer Version\t1.1.0.32", "[Experiment Logs]\t", "Experiment Log Entry # 1\tGas Select Segment is 1", "Experiment Log Entry # 3\tEquilibrate Segment 30 (C) Started", "Experiment Log Entry # 5\tIsothermal Segment 3 min started", "Experiment Log Entry # 7\tRamp Segment 10 C/min to 750 C Started", "Experiment Log Entry # 9\tIsothermal Segment 5 min started", "Experiment Log Entry # 11\tGas Select Segment is 2", "Experiment Log Entry # 13\tIsothermal Segment 10 min started", "[Method Log]\t", "Method Log Entry # 1\tGas Selected 1", "Method Log Entry # 2\tEquilibrate 30 °C", "Method Log Entry # 3\tIsothermal 3 minutes", "Method Log Entry # 4\t(Ramp 88036) Ramp 10 °C/minute to 750 °C", "Method Log Entry # 5\tIsothermal 5 minutes", "Method Log Entry # 6\tGas Selected 2", "Method Log Entry # 7\tIsothermal 10 minutes", "[Weight Calibration]\t", "Date Applied\t14.06.2023 07:39:55", "Empty Pan Number\t23.0", "Empty Pan Weight\t325.000 mg", "Low Reference Weight Pan Number\t24.0", "Low Reference Weight\t425.000 mg", "High Reference Weight Pan Number\t25.0", "High Reference Weight\t1,325.000 mg", "Low Gain Meter Reading\t9.5856E-006 mg/count", "High Gain Meter Reading\t8.6100E-005 mg/count", "Low Meter Offset\t47.9314 mg", "High Meter Offset\t684.5124 mg", "[Curie Calibration]\t", "Date Applied\t14.06.2023 07:05:13", "Description\tFrom 308.200 °C to 408.200 °C at 10.000°C/min", "Gas Type\tNitrogen", "Pan Type\tPlatinum HT", "Source Files 1\tC:\\Users\\ITCP-AKT.ITCP-AKT-003\\Documents\\Nickel(6).tri", "Measured 1\t355.8379", "Known 1\t358.2" ], "metadata": { "Comments": "", "Common IDD Version": 1, "Company Name": "KIT", "Cortex Version": "VER 2.1.2.69", "Current File Name": "C:\\Users\\ITCP-AKT.ITCP-AKT-003\\Documents\\DD-F41.tri", "Date Applied": "14.06.2023 07:39:55", "Date Applied (1)": "14.06.2023 07:05:13", "Description": "From 308.200 °C to 408.200 °C at 10.000°C/min", "DisplayType": "TianmaV2", "Driver": "5.0.0.7", "Empty Pan Number": 23, "Empty Pan Weight": "325.000 mg", "Experiment Log Entry # 1": "Gas Select Segment is 1", "Experiment Log Entry # 11": "Gas Select Segment is 2", "Experiment Log Entry # 13": "Isothermal Segment 10 min started", "Experiment Log Entry # 3": "Equilibrate Segment 30 (C) Started", "Experiment Log Entry # 5": "Isothermal Segment 3 min started", "Experiment Log Entry # 7": "Ramp Segment 10 C/min to 750 C Started", "Experiment Log Entry # 9": "Isothermal Segment 5 min started", "Filename": "DD-F41", "GDM Version": "1.2.1.2", "Gas 1": "Nitrogen", "Gas 2": "Air", "Gas Type": "Nitrogen", "High Gain Meter Reading": "8.6100E-005 mg/count", "High Meter Offset": "684.5124 mg", "High Reference Weight": "1,325.000 mg", "High Reference Weight Pan Number": 25, "IP": "192.168.1.99", "Instrument Name": "5500-0290", "Instrument Type": "TGA5500", "Instrument name": "5500-0290 (192.168.1.99)", "Known 1": 358.2, "Location of Instrument": "Manufacturing Test", "Low Gain Meter Reading": "9.5856E-006 mg/count", "Low Meter Offset": "47.9314 mg", "Low Reference Weight": "425.000 mg", "Low Reference Weight Pan Number": 24, "MTGA HiRes Licensed": "Yes", "Measured 1": 355.8379, "Method Log Entry # 1": "Gas Selected 1", "Method Log Entry # 2": "Equilibrate 30 °C", "Method Log Entry # 3": "Isothermal 3 minutes", "Method Log Entry # 4": "(Ramp 88036) Ramp 10 °C/minute to 750 °C", "Method Log Entry # 5": "Isothermal 5 minutes", "Method Log Entry # 6": "Gas Selected 2", "Method Log Entry # 7": "Isothermal 10 minutes", "Operator": "", "Operator (1)": "", "Original File Name": "", "PCU Version": "1.2.0.22", "Pan Number": 2, "Pan Type": "Platinum HT", "Pan Type (1)": "Platinum HT", "Procedure Name": "DD Standard 800 °C", "Project Name": "", "Run date": "28.06.2023 14:37:28", "Sample Mass": "9.960 mg", "Sample Name": "DD-F41", "Sample mass pre-weigh": "Not Available", "Sample name": "DD-F41", "Sampling Rate": 0.1, "Selected Gas Channel": 1, "Serial Number": "5500-0290", "Signal #1": "Time (min)", "Signal #2": "Temperature (°C)", "Signal #3": "Weight (µg)", "Signal #4": "Temperature Difference (°C)", "Signal #5": "Sample Purge (mL/min)", "Signal #6": "Balance Purge (mL/min)", "Signal #7": "Set Point Temperature (°C)", "Signal #8": "Power Delivered (W)", "Signal #9": "Ramp Rate (°C/min)", "Skip Weight Stabilization": 1, "Source Files 1": "C:\\Users\\ITCP-AKT.ITCP-AKT-003\\Documents\\Nickel(6).tri", "Stop on Gas Flow Error": "Yes", "Test": "Custom", "TouchscreenVersion": "1.0.0.14551", "Transducer Version": "1.1.0.32", "Trios version": "5.0.0.44608", "[Configuration]": "", "[Curie Calibration]": "", "[Experiment Logs]": "", "[File Parameters]": "", "[Method Log]": "", "[Procedure]": "", "[Signal List]": "", "[Versions]": "", "[Weight Calibration]": "", "columns": "0", "proceduresegments": "Select Gas: Gas 1 ; Equilibrate 30.00 °C; Isothermal 3.0 min; Ramp 10.00 °C/min to 750.00 °C; Isothermal 5.0 min; Select Gas: Gas 2 ; Isothermal 10.0 min", "rows": "0", "rundate": "28.06.2023" }, "rows": [] }, { "columns": [ { "key": "0", "name": "Column #0" }, { "key": "1", "name": "Column #1" }, { "key": "2", "name": "Column #2" }, { "key": "3", "name": "Column #3" } ], "header": [ "Isothermal 3.0 min\t\t\t", "Time\tTemperature\tWeight\tWeight", "min\t°C\tµg\t%" ], "metadata": { "Isothermal 3.0 min": "", "Isothermal 3.0 min (1)": "", "Isothermal 3.0 min (2)": "", "Time": "Temperature", "Time (1)": "Weight", "Time (2)": "Weight", "columns": "4", "min": "°C", "min (1)": "µg", "min (2)": "%", "rows": "1800" }, "rows": [ [ 0, 29.79, 9916.2, 99.56 ], [ 0.00166667, 29.79, 9916.16, 99.56 ], [ 0.00333333, 29.79, 9916.13, 99.56 ], [ 0.005, 29.79, 9916.09, 99.56 ], [ 0.00666667, 29.79, 9916.05, 99.56 ], [ 0.00833333, 29.79, 9916.01, 99.56 ], [ 0.01, 29.79, 9915.97, 99.56 ], [ 0.0116667, 29.79, 9915.93, 99.56 ], [ 0.0133333, 29.8, 9915.9, 99.56 ], [ 0.015, 29.8, 9915.86, 99.56 ] ] }, { "columns": [ { "key": "0", "name": "Column #0" }, { "key": "1", "name": "Column #1" }, { "key": "2", "name": "Column #2" }, { "key": "3", "name": "Column #3" } ], "header": [ "Ramp 10.00 °C/min to 750.00 °C\t\t\t", "Time\tTemperature\tWeight\tWeight", "min\t°C\tµg\t%" ], "metadata": { "Ramp 10.00 °C/min to 750.00 °C": "", "Ramp 10.00 °C/min to 750.00 °C (1)": "", "Ramp 10.00 °C/min to 750.00 °C (2)": "", "Time": "Temperature", "Time (1)": "Weight", "Time (2)": "Weight", "columns": "4", "min": "°C", "min (1)": "µg", "min (2)": "%", "rows": "43391" }, "rows": [ [ 3, 29.73, 9866.36, 99.06 ], [ 3.00167, 29.73, 9866.34, 99.06 ], [ 3.00333, 29.73, 9866.32, 99.06 ], [ 3.005, 29.73, 9866.3, 99.06 ], [ 3.00667, 29.73, 9866.28, 99.06 ], [ 3.00833, 29.73, 9866.26, 99.06 ], [ 3.01, 29.73, 9866.24, 99.06 ], [ 3.01167, 29.73, 9866.22, 99.06 ], [ 3.01333, 29.73, 9866.2, 99.06 ], [ 3.015, 29.73, 9866.18, 99.06 ] ] }, { "columns": [ { "key": "0", "name": "Column #0" }, { "key": "1", "name": "Column #1" }, { "key": "2", "name": "Column #2" }, { "key": "3", "name": "Column #3" } ], "header": [ "Isothermal 5.0 min\t\t\t", "Time\tTemperature\tWeight\tWeight", "min\t°C\tµg\t%" ], "metadata": { "Isothermal 5.0 min": "", "Isothermal 5.0 min (1)": "", "Isothermal 5.0 min (2)": "", "Time": "Temperature", "Time (1)": "Weight", "Time (2)": "Weight", "columns": "4", "min": "°C", "min (1)": "µg", "min (2)": "%", "rows": "3000" }, "rows": [ [ 75.3183, 748.21, 2669.97, 26.81 ], [ 75.32, 748.23, 2669.95, 26.81 ], [ 75.3217, 748.24, 2669.92, 26.81 ], [ 75.3233, 748.26, 2669.89, 26.81 ], [ 75.325, 748.27, 2669.86, 26.81 ], [ 75.3267, 748.29, 2669.83, 26.81 ], [ 75.3283, 748.31, 2669.8, 26.81 ], [ 75.33, 748.32, 2669.77, 26.81 ], [ 75.3317, 748.34, 2669.75, 26.81 ], [ 75.3333, 748.36, 2669.72, 26.81 ] ] }, { "columns": [ { "key": "0", "name": "Column #0" }, { "key": "1", "name": "Column #1" }, { "key": "2", "name": "Column #2" }, { "key": "3", "name": "Column #3" } ], "header": [ "Isothermal 10.0 min\t\t\t", "Time\tTemperature\tWeight\tWeight", "min\t°C\tµg\t%" ], "metadata": { "Isothermal 10.0 min": "", "Isothermal 10.0 min (1)": "", "Isothermal 10.0 min (2)": "", "Time": "Temperature", "Time (1)": "Weight", "Time (2)": "Weight", "columns": "4", "min": "°C", "min (1)": "µg", "min (2)": "%", "rows": "6000" }, "rows": [ [ 80.3183, 749.96, 2613.37, 26.24 ], [ 80.32, 749.96, 2613.35, 26.24 ], [ 80.3217, 749.96, 2613.33, 26.24 ], [ 80.3233, 749.96, 2613.31, 26.24 ], [ 80.325, 749.96, 2613.29, 26.24 ], [ 80.3267, 749.96, 2613.26, 26.24 ], [ 80.3283, 749.96, 2613.24, 26.24 ], [ 80.33, 749.96, 2613.23, 26.24 ], [ 80.3317, 749.96, 2613.21, 26.24 ], [ 80.3333, 749.96, 2613.19, 26.24 ] ] } ] }, "description": "TGA - Campus West, KIT with Isothermal", "id": "e7a4ee04-cdf6-4da6-a82c-ba6909af6cee", "identifiers": [ { "key": "reader", "match": "exact", "optional": false, "type": "fileMetadata", "value": "OldExcelReader" }, { "key": "Instrument Type", "match": "exact", "optional": false, "tableIndex": 0, "type": "tableMetadata", "value": "TGA5500" }, { "lineNumber": 1, "match": "regex", "optional": false, "tableIndex": 2, "type": "tableHeader", "value": "Ramp" } ], "tables": [ { "header": { "DATA CLASS": "XYPOINTS", "DATA TYPE": "THERMOGRAVIMETRIC ANALYSIS", "XUNITS": "DEGREES CELSIUS", "YUNITS": "Weight %" }, "table": { "xColumn": { "columnIndex": 1, "tableIndex": 2 }, "yColumn": { "columnIndex": 3, "tableIndex": 2 } } }, { "header": { "DATA CLASS": "XYPOINTS", "DATA TYPE": "THERMOGRAVIMETRIC ANALYSIS", "XUNITS": "DEGREES CELSIUS", "YUNITS": "Weight %" }, "table": { "xColumn": { "columnIndex": 1, "tableIndex": 1 }, "yColumn": { "columnIndex": 3, "tableIndex": 1 } } } ], "title": "TGA" }