METADATA last updated: 2025-12-15 RT updated metadata after BA fixed inconsistencies file_name: Site Checklist - Alpine.md file_date: 2022-05-24 title: Test Site Checklist - Alpine category: guides subcategory: test-site tags: source_file_type: gdoc xfile_type: docx gfile_url: https://docs.google.com/document/d/1qeZHKgUPQ7ENf7JxHa9MjvVvWuVkw0IUbxPmbd0U9-A xfile_github_download_url: https://raw.githubusercontent.com/FocusOnFoundationsNonprofit/floodlamp-archive/main/guides/test-site/Site%20Checklist%20-%20Alpine.docx pdf_gdrive_url: https://drive.google.com/file/d/1PKufMY-68iBrvLUC6dRfTwBpOqOZSQh- pdf_github_url: https://github.com/FocusOnFoundationsNonprofit/floodlamp-archive/blob/main/guides/test-site/Site%20Checklist%20-%20Alpine.pdf conversion_input_file_type: docx conversion: pandoc license: CC BY 4.0 - https://creativecommons.org/licenses/by/4.0/ tokens: 836 words: 544 notes: summary_short: The Test Site Checklist – Alpine provides step-by-step daily, weekly, and readiness checklists for running FloodLAMP testing at the Alpine site, including setup, reagent/consumables checks, intake logistics, run timing, rerun decision-making, and end-of-day cleanup. It standardizes site operations and communication (via the designated Slack channel) to ensure consistent testing workflow, inventory control, and equipment readiness. CONTENT ## Testing Checklist - Alpine v1.1 Last updated: 5-24-2022 RT GW BS For all ***communication*** steps specified below, use the Slack channel: **\# testing-alpine_portola** ### Before Arrival - Confirm Heaters turned on (text Randy & Theresa if confirmation not received by 8am) ### Upon Arrival Time: - Prepare 10% Bleach Solution - Double check water bath up to temp - Clean Inactivation Table - Set up Inactivation Table - Check sufficient 1XISS (or make) and Rxn Mix (frozen or source tubes), and *not expired* - Check sufficient consumables for usage (1.5mL tubes, strip-8s, tips, reservoirs) - Ensure you have expected tubes from staff - Check red mailbox for tubes CODE: 513 ### At Carillon Time: - Travel to Carillon and set up at drop off point - Intake Collection tubes already dropped off - Continue intaking as participants drop off tubes until cut off time 9:05 - ***Communicate*** intake anomalies (QR code and anomaly description) ### Upon Return to Alpine Time: - Turn off air purifiers before beginning the test procedure. Keep the door closed. - Run test - When on amp, ***communicate*** time expected to remove from amp - Check with FL Program Admin if positives are known or unknown. Rerun if unknown. - ***Communicate*** Result image & lookup map Time: - Mark result on lookup map as a circled ‘P’ or ‘I’ at the end of the tube code - Wait 5 mins for confirmation of whether any positives are known positives - ***Communicate*** re-run plan for all inconclusives and unknown positives I.e.: “re-running 1 positive, 1 inconclusive in triplicate” - Re-run test - ***Communicate*** re-run results ETA - ***Communicate*** final results and time Time: - Return cold blocks to freezer - Return pipettes, tip boxes, racks - Check that all thawed inactivation solution bottles & vials are covered in foil - Discard sample tubes from refrigerator (neg. in trash, pos. in bag in bottom freezer) - Turn off heaters - Empty and clean tip buckets with bleach and ethanol ## Weekly Checklist - Alpine v1.1 - Update complete Inventory - Submit inventory to FL - Audit freezer sensor data for anomalies - Check Expiration dates of reagents - Empty trash bins - OPTIONALLY: Prepare reaction tubes for the week, and freeze - AS NEEDED: receive deliveries - Use included ship list to verify contents - ***Communicate*** any discrepancies to **\# testing - alpine** - Update Inventory with new materials ## State Of Readiness Checklist - Alpine v1.1 - Glove boxes BOTH in assay prep room AND amplification area - Wipes present (one active, plus extra on supply shelf) - Empty Tip box filled with strip tubes (fill tip box + half source box) - Falcon Tubes Filled with strip tube caps (two full falcon tubes, + half source box) - 1.5mL tubes closed and in cleaned, labeled cryobox (1 active box, Next box fully ready) - At least 5 blank Amp run forms, and at least 1 spare of both table forms (1X ISS & RM) - Pens and markers clean and in proper place - Pens tested and functional - Spare tube of inactivation solution in freezer - Freezer thermometer tested and functional - Lightbox battery charged and functional - Old non-significant samples clear from fridge - Tip buckets empty