Fresh saved-model/ELF inspection run. No hardware or GUI execution.

verify_debounce.py
{
  "scope": "Synthetic sampled-input arithmetic only; RC, contact physics, MCU execution and physical timing are not simulated.",
  "qualification_ms": 20,
  "cases_passed": [
    "bouncing press and release",
    "release does not toggle",
    "second press",
    "boot held does not create press",
    "short pulse rejected",
    "19/20 ms boundary",
    "held press counted once",
    "uint32 tick wrap",
    "sampling can miss transitions"
  ],
  "sampled_edges_1ms": 9,
  "sampled_edges_10ms": 3,
  "accepted_presses": 2
}

calculate_baseline.py
{
  "scope": "Nominal arithmetic only. External RC values do not guarantee contact debounce; HSI physical frequency and actual loop timing not measured.",
  "external_pullup_ohm": 10000,
  "capacitor_farad": 1e-07,
  "nominal_RC_ms": 1.0,
  "configured_HCLK_hz": 8000000,
  "default_HAL_SysTick_hz": 1000,
  "expected_SysTick_reload": 7999,
  "qualification_ms": 20
}