Validation Log 2025-12-14 21:00:24.391161 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000041/mwtab/json Study ID: ST000022 Analysis ID: AN000041 File format: json Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 0 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: The value, "Average age 68.1(9.12)", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "Average BMI of 31.4(7.01)", in ["SUBJECT"]["WEIGHT_OR_WEIGHT_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["TREATMENT"]["TREATMENT_SUMMARY"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["EXTRACTION_METHOD"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The value, "0.5mm", in ["NM"]["STANDARD_CONCENTRATION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mM']. Ignore this when more complicated descriptions are required. Error: The value, "12.589w", in ["NM"]["POWER_LEVEL"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['W', 'dB']. Ignore this when more complicated descriptions are required. Error: The value, "4468.31", in ["NM"]["OFFSET_FREQUENCY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "18939.395 Hz, 19.93 ppm", in ["NM"]["SPECTRAL_WIDTH"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "0.5", in ["NM"]["LINE_BROADENING"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['Hz']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid sections, "CHROMATOGRAPHY", "Data". Error: There must be either a "NMR_METABOLITE_DATA" section, a "NMR_BINNED_DATA" section or a "NMR_RESULTS_FILE" subsection in the "NM" section. Neither were found.