Validation Log 2025-12-14 21:05:47.954128 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000135/mwtab/json Study ID: ST000083 Analysis ID: AN000135 File format: json Status: Contains Validation Issues Number of Issues: 20 Number of Warnings: 8 Number of Value Errors: 15 Number of Consistency Errors: 0 Number of Format Errors: 4 Issue Log: Error: An empty value or a null value was detected in ["PROJECT"]["ADDRESS"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["PROJECT"]["PHONE"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["STUDY"]["ADDRESS"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["STUDY"]["PHONE"]. A legitimate value should be provided for this required key. Error: The value, "6- to 8-week-old", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "0.450.5 mL/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "1 L, splitless", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "10 L", in ["CHROMATOGRAPHY"]["SAMPLE_SYRINGE_SIZE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "COLUMN_TEMPERATURE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "ri" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "moverz_quant" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri_type" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "inchi_key" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "kegg_id" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values.