Validation Log 2025-12-14 21:05:49.388522 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000136/mwtab/txt Study ID: ST000084 Analysis ID: AN000136 File format: txt Status: Contains Validation Issues Number of Issues: 21 Number of Warnings: 8 Number of Value Errors: 14 Number of Consistency Errors: 2 Number of Format Errors: 4 Issue Log: Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: The value, "0.45-0.5mL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "1 L, Splitless", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "10 L", for the subsection, "SAMPLE_SYRINGE_SIZE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Error: The following metabolites in the, MS_METABOLITE_DATA table were not found in the METABOLITES table: "5^-deoxy-5^-(methylthio)adenosine" "guanosine-5^-monophosphate" "uridine 5^-monophosphate" Error: The following metabolites in the METABOLITES table were not found in the MS_METABOLITE_DATA table: "5'-deoxy-5'-(methylthio)adenosine" "guanosine-5'-monophosphate" "uridine 5'-monophosphate" Warning: The "ri" column at position 3 in the METABOLITES table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the METABOLITES table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "moverz_quant" column at position 2 in the METABOLITES table has all null values. Warning: The "ri" column at position 3 in the METABOLITES table has all null values. Warning: The "ri_type" column at position 4 in the METABOLITES table has all null values. Warning: The "inchi_key" column at position 6 in the METABOLITES table has all null values. Warning: The "kegg_id" column at position 7 in the METABOLITES table has all null values.