Validation Log 2025-12-14 21:05:57.233613 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000139/mwtab/json Study ID: ST000087 Analysis ID: AN000139 File format: json Status: Contains Validation Issues Number of Issues: 25 Number of Warnings: 7 Number of Value Errors: 17 Number of Consistency Errors: 1 Number of Format Errors: 4 Issue Log: Error: An empty value or a null value was detected in ["COLLECTION"]["COLLECTION_SUMMARY"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["TREATMENT"]["TREATMENT_SUMMARY"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["SAMPLEPREP_SUMMARY"]. A legitimate value should be provided for this required key. Error: The value, "250°C", in ["MS"]["ION_SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "70eV", in ["MS"]["IONIZATION_ENERGY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['eV']. Ignore this when more complicated descriptions are required. Error: The value, "250°C", in ["MS"]["SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1 ml/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "50 - 330C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "0.5l", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "7.7 PSI (initial condition)", in ["CHROMATOGRAPHY"]["COLUMN_PRESSURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'bar']. Ignore this when more complicated descriptions are required. Error: The value, "50C ramped to 250C by 12C/s", in ["CHROMATOGRAPHY"]["INJECTION_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "230C", in ["CHROMATOGRAPHY"]["TRANSFERLINE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "30 m length x 0.25 mm internal diameter", in ["CHROMATOGRAPHY"]["SAMPLE_LOOP_SIZE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Error: SUBJECT_SAMPLE_FACTORS section missing sample ID(s). The following IDs were found in the ["MS_METABOLITE_DATA"]["Data"] section but not in the SUBJECT_SAMPLE_FACTORS: "NoCellCultureMedia(MediaBlank)" "QCPellet020414" "S17D" "S17E" "S17E_QC" "S17F" "S19D" "S19E" "S20D" "S20E" "S20F" "S24D" "S24E" "S25D" "S25E" "S26D" "S26E" Warning: The "Quant m/z" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Spectra" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "mass_spectrum". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Other ID" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "other_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Ret. Index" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column "Other ID" was found in the ["MS_METABOLITE_DATA"]["Metabolites"] table, but this column implies that another column, "other_id_type", should also exist, and that column was not found. Warning: The column "Ret. Index" was found in the ["MS_METABOLITE_DATA"]["Metabolites"] table, but this column implies that another column, "retention_index_type", should also exist, and that column was not found. Warning: The standard column, "other_id", was found in the METABOLITES table as "Other ID". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Error: The ["MS_METABOLITE_DATA"]["Data"] table does not have a column for "Metabolite". It is likely misspelled or using a common incorrect substitute.