Validation Log 2025-12-14 21:06:55.651138 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000153/mwtab/json Study ID: ST000096 Analysis ID: AN000153 File format: json Status: Contains Validation Issues Number of Issues: 19 Number of Warnings: 8 Number of Value Errors: 15 Number of Consistency Errors: 0 Number of Format Errors: 3 Issue Log: Error: The value, "See protocol/methods file", in ["MS"]["ION_SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "See protocol/methods file", in ["MS"]["ION_SPRAY_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "0.25", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "5 L", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "600 L", in ["CHROMATOGRAPHY"]["WEAK_WASH_VOLUME"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "600 L", in ["CHROMATOGRAPHY"]["STRONG_WASH_VOLUME"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "17 L", in ["CHROMATOGRAPHY"]["SAMPLE_LOOP_SIZE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "CHROMATOGRAPHY_TYPE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "INSTRUMENT_NAME", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "COLUMN_NAME", in ["CHROMATOGRAPHY"] is missing. Warning: The "ri" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Error: Column(s) with no name were found in the ["MS_METABOLITE_DATA"]["Metabolites"] table. Warning: The "inchi_key" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri_type" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "moverz_quant" column at position 9 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "" column at position 10 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values.