Validation Log 2025-12-14 21:07:02.470121 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000156/mwtab/txt Study ID: ST000097 Analysis ID: AN000156 File format: txt Status: Contains Validation Issues Number of Issues: 8 Number of Warnings: 0 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected for the subsection, "PROJECT_SUMMARY", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: The value, "4.77", for the subsection, "OFFSET_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "22 degree Celsius", for the subsection, "TEMPERATURE", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: The value, "2.3s", for the subsection, "ACQUISITION_TIME", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s']. Ignore this when more complicated descriptions are required. Error: The value, "2s", for the subsection, "RELAXATION_DELAY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s', 'ms', 'us', 'μs']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY".