Comparison Log 2025-12-14 21:07:11.332312 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000159/mwtab/... Study ID: ST000098 Analysis ID: AN000159 Status: Inconsistent Sections "MS" contain missmatched items: {'MS_COMMENTS': ['HSP_F10_ms2_neg.raw, HSP_F9_ms2_neg.raw Samples were analyzed using a mass range of 70-1000 in positive and negative modes, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap spectrometer equipped with a Dionex UltiMate 3000 RS autosampler and pump. The was equipped with a Heated Electrospray Ionization (HESI) source which operated a spray temperature of 350 ?C, a spray voltage of 3.5 kV, and sheath and gas flow rates of 50 and 10 arbitrary units, respectively. The capillary was held at 325 ?C, and the S-lens RF Level was set to 40%. The FR resolution set to 70,000 at m/z 200. The accuracy achieved was routinely less than 1.5 In addition to full MS, data-dependent MS/MS was performed on the 10 most peaks with an exclusion period of 10 seconds (40 normalized collision energy). was performed using a Dionex UltiMate 3000 fraction collector by triggering 30 seconds.', 'Samples were analyzed using a mass range of 70-1000 in positive and negative modes, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap spectrometer equipped with a Dionex UltiMate 3000 RS autosampler and pump. The was equipped with a Heated Electrospray Ionization (HESI) source which operated a spray temperature of 350 ?C, a spray voltage of 3.5 kV, and sheath and gas flow rates of 50 and 10 arbitrary units, respectively. The capillary was held at 325 ?C, and the S-lens RF Level was set to 40%. The FR resolution set to 70,000 at m/z 200. The accuracy achieved was routinely less than 1.5 In addition to full MS, data-dependent MS/MS was performed on the 10 most peaks with an exclusion period of 10 seconds (40 normalized collision energy). was performed using a Dionex UltiMate 3000 fraction collector by triggering 30 seconds.']}