Validation Log 2025-12-14 21:07:12.585233 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000160/mwtab/txt Study ID: ST000098 Analysis ID: AN000160 File format: txt Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 0 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "STUDY_SUMMARY", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: The value, "37", for the subsection, "POWER_LEVEL", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['W', 'dB']. Ignore this when more complicated descriptions are required. Error: The value, "4.77", for the subsection, "OFFSET_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "23d", for the subsection, "TEMPERATURE", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: The value, "0.14", for the subsection, "ACQUISITION_TIME", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s']. Ignore this when more complicated descriptions are required. Error: The value, "1.5 sec", for the subsection, "RELAXATION_DELAY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s', 'ms', 'us', 'μs']. Ignore this when more complicated descriptions are required. Error: The value, "12 ppm ; 205.5 ppm", for the subsection, "SPECTRAL_WIDTH", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "2", for the subsection, "LINE_BROADENING", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['Hz']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY". Error: There must be either a "NMR_METABOLITE_DATA" section, a "NMR_BINNED_DATA" section or a "NMR_RESULTS_FILE" subsection in the "NM" section. Neither were found.