Validation Log 2025-12-14 21:07:37.165205 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000170/mwtab/txt Study ID: ST000102 Analysis ID: AN000170 File format: txt Status: Contains Validation Issues Number of Issues: 18 Number of Warnings: 0 Number of Value Errors: 16 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: The value, "5-7 day-old adults (mated)", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "0.17-0.77mg", for the subsection, "WEIGHT_OR_WEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: The value, "NA", for the subsection, "HEIGHT_OR_HEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['cm', 'in']. Ignore this when more complicated descriptions are required. Error: The value, "3h", for the subsection, "TREATMENT_DOSEDURATION", in the "TREATMENT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['h', 'weeks', 'days']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "SAMPLEPREP_SUMMARY", in the "SAMPLEPREP" section. A legitimate value should be provided for this required subsection. Error: The value, "1 mM TMSP", for the subsection, "STANDARD_CONCENTRATION", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mM']. Ignore this when more complicated descriptions are required. Error: The value, "f1 -1.00 dB, f2 -4.13 dB", for the subsection, "POWER_LEVEL", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['W', 'dB']. Ignore this when more complicated descriptions are required. Error: The value, "f2 3294.95 Hz, f1 14081.41 Hz", for the subsection, "OFFSET_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "f2 0.13317 s, f1 0.0083333 s", for the subsection, "ACQUISITION_TIME", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s']. Ignore this when more complicated descriptions are required. Error: The value, "f2 10.9888, f1 180.00", for the subsection, "SPECTRAL_WIDTH", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "f2 2048, f1 528", for the subsection, "NUM_DATA_POINTS_ACQUIRED", in the "NM" section should be a unitless number. Ignore this when more complicated descriptions are required. Error: The value, "f2 1.0 Hz, f1 0.3 Hz", for the subsection, "LINE_BROADENING", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['Hz']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY". Error: There must be either a "NMR_METABOLITE_DATA" section, a "NMR_BINNED_DATA" section or a "NMR_RESULTS_FILE" subsection in the "NM" section. Neither were found.