Validation Log 2025-12-14 21:08:54.163912 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000197/mwtab/json Study ID: ST000116 Analysis ID: AN000197 File format: json Status: Contains Validation Issues Number of Issues: 17 Number of Warnings: 4 Number of Value Errors: 14 Number of Consistency Errors: 2 Number of Format Errors: 0 Issue Log: Error: An empty value or a null value was detected in ["PROJECT"]["PROJECT_SUMMARY"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["PROJECT"]["PHONE"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["STUDY"]["PHONE"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["TREATMENT"]["TREATMENT_SUMMARY"]. A legitimate value should be provided for this required key. Error: The value, "POSITIVE/NEGATIVE", in ["MS"]["ION_MODE"] should be one of "Positive", "Negative", "Positive, Negative", or "Unspecified". Ignore this when more complicated descriptions are required. Error: The value, "N2", in ["MS"]["COLLISION_GAS"] should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "350°C", in ["MS"]["DRY_GAS_TEMP"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["MS"]["MS_COMMENTS"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The value, "40C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "10 ?L", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "18 MPa", in ["CHROMATOGRAPHY"]["COLUMN_PRESSURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'bar']. Ignore this when more complicated descriptions are required. Error: The following metabolites in the, ["MS_METABOLITE_DATA"]["Data"] table were not found in the ["MS_METABOLITE_DATA"]["Metabolites"] table: "2_6-Diaminoheptanedioate" "5_6-Dihydrouracil" "5^-Methylthioadenosine" "7_8-Diaminononanoate" "Fructose 1_6-bisphosphate" "Pantetheine 4^-phosphate" "Sedoheptulose 1_7-bisphosphate" Error: The following metabolites in the ["MS_METABOLITE_DATA"]["Metabolites"] table were not found in the ["MS_METABOLITE_DATA"]["Data"] table: "2,6-Diaminoheptanedioate" "5,6-Dihydrouracil" "5'-Methylthioadenosine" "7,8-Diaminononanoate" "Fructose 1,6-bisphosphate" "Pantetheine 4'-phosphate" "Sedoheptulose 1,7-bisphosphate" Warning: The "ri" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "inchi_key" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values.