Validation Log 2025-12-14 21:08:58.618388 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000199/mwtab/txt Study ID: ST000118 Analysis ID: AN000199 File format: txt Status: Contains Validation Issues Number of Issues: 26 Number of Warnings: 9 Number of Value Errors: 21 Number of Consistency Errors: 1 Number of Format Errors: 3 Issue Log: Error: An empty value or a null value was detected for the subsection, "PROJECT_SUMMARY", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "COLLECTION_SUMMARY", in the "COLLECTION" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "SAMPLEPREP_SUMMARY", in the "SAMPLEPREP" section. A legitimate value should be provided for this required subsection. Error: The value, "250°C", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "-70eV", for the subsection, "IONIZATION_ENERGY", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['eV']. Ignore this when more complicated descriptions are required. Error: The value, "1ml/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "50-330oC", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "0.5uL", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "280C", for the subsection, "TRANSFERLINE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "30 m length x 0.25 mm internal diameter", for the subsection, "SAMPLE_LOOP_SIZE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Error: The following metabolites in the, MS_METABOLITE_DATA table were not found in the METABOLITES table: "1_5-anhydroglucitol" "2_5-dihydroxypyrazine NIST" "3_6-anhydro-D-galactose" "dodecanoic acid_ isopropanol ester NIST" "inosine 5^-monophosphate" "propane-1_3-diol NIST" Warning: The "inchi_key" column at position 6 in the METABOLITES table, matches a standard column name, "inchi_key", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 132 C00077 Warning: The "pubchem_id" column at position 5 in the METABOLITES table, matches a standard column name, "pubchem_id", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 132 AHLPHDHHMVZTML-BYPYZUCNSA-N Warning: The "kegg_id" column at position 7 in the METABOLITES table, matches a standard column name, "kegg_id", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 71 0 Warning: The "ri" column at position 3 in the METABOLITES table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the METABOLITES table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the METABOLITES table, matches a standard column name, "retention_index_type", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 132 6262 Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "ri_type" column at position 4 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "other_id_type" column at position 9 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.