Validation Log 2025-12-14 21:09:11.310068 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000202/mwtab/json Study ID: ST000120 Analysis ID: AN000202 File format: json Status: Contains Validation Issues Number of Issues: 25 Number of Warnings: 9 Number of Value Errors: 21 Number of Consistency Errors: 2 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected in ["PROJECT"]["ADDRESS"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["STUDY"]["ADDRESS"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["STUDY"]["PHONE"]. A legitimate value should be provided for this required key. Error: The value, "adult", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["COLLECTION"]["COLLECTION_SUMMARY"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["TREATMENT"]["TREATMENT_SUMMARY"]. A legitimate value should be provided for this required key. Error: The value, "N2", in ["MS"]["COLLISION_GAS"] should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "150C", in ["MS"]["SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "600 L/h", in ["MS"]["DESOLVATION_GAS_FLOW"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "350C", in ["MS"]["DESOLVATION_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "0.15 ml/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "10ul", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "12 mins", in ["CHROMATOGRAPHY"]["ANALYTICAL_TIME"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['min']. Ignore this when more complicated descriptions are required. Error: The required property, "COLUMN_TEMPERATURE", in ["CHROMATOGRAPHY"] is missing. Error: The following metabolites in the, ["MS_METABOLITE_DATA"]["Data"] table were not found in the ["MS_METABOLITE_DATA"]["Metabolites"] table: "Corticosterone_ DOC" Error: The following metabolites in the ["MS_METABOLITE_DATA"]["Metabolites"] table were not found in the ["MS_METABOLITE_DATA"]["Data"] table: "Corticosterone, DOC" Warning: The "ri" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "10 MZD Liver F" column at position 77 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "moverz_quant" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri_type" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "inchi_key" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "kegg_id" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values.