Validation Log 2025-12-14 21:18:10.372679 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000384/mwtab/txt Study ID: ST000246 Analysis ID: AN000384 File format: txt Status: Contains Validation Issues Number of Issues: 17 Number of Warnings: 10 Number of Value Errors: 15 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: An empty value or a null value was detected for the subsection, "COLLECTION_SUMMARY", in the "COLLECTION" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: The value, "320", for the subsection, "CAPILLARY_TEMPERATURE", in the "MS" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "30", for the subsection, "DRY_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, ".raw", for the subsection, "DESOLVATION_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "1241 bar (max)", for the subsection, "COLUMN_PRESSURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'bar']. Ignore this when more complicated descriptions are required. Warning: The "ri" column at position 3 in the METABOLITES table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the METABOLITES table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column pair, "other_id" and "other_id_type", in the METABOLITES table should have data in the same rows, but at least one row has data in one column and nothing in the other. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "ri" column at position 3 in the METABOLITES table has all null values. Warning: The "ri_type" column at position 4 in the METABOLITES table has all null values. Warning: The "pubchem_id" column at position 5 in the METABOLITES table has all null values. Warning: The "inchi_key" column at position 6 in the METABOLITES table has all null values. Warning: The "kegg_id" column at position 7 in the METABOLITES table has all null values. Warning: The "other_id" column at position 8 in the METABOLITES table has all null values.