Validation Log 2025-12-14 21:19:23.703822 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000410/mwtab/json Study ID: ST000258 Analysis ID: AN000410 File format: json Status: Contains Validation Issues Number of Issues: 19 Number of Warnings: 8 Number of Value Errors: 12 Number of Consistency Errors: 2 Number of Format Errors: 3 Issue Log: Error: The required property, "COLLECTION_SUMMARY", in ["COLLECTION"] is missing. Error: An empty value or a null value was detected in ["TREATMENT"]["ANIMAL_ENDP_CLINICAL_SIGNS"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The required property, "TREATMENT_SUMMARY", in ["TREATMENT"] is missing. Error: The required property, "SAMPLEPREP_SUMMARY", in ["SAMPLEPREP"] is missing. Error: The value, "250ºC", in ["MS"]["DRY_GAS_TEMP"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "200 ?L/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "2 ?L", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The following metabolites in the, ["MS_METABOLITE_DATA"]["Data"] table were not found in the ["MS_METABOLITE_DATA"]["Metabolites"] table: "ADP_ Na-2H adduct" "glucose_ Cl adduct" "L-2_3-Dihydrodipicolinate" Error: The following metabolites in the ["MS_METABOLITE_DATA"]["Metabolites"] table were not found in the ["MS_METABOLITE_DATA"]["Data"] table: "ADP, Na-2H adduct" "glucose, Cl adduct" "L-2,3-Dihydrodipicolinate" Warning: The "ri" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column pair, "other_id" and "other_id_type", in the METABOLITES table should have data in the same rows, but at least one row has data in one column and nothing in the other. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Error: Column(s) with no name were found in the ["MS_METABOLITE_DATA"]["Metabolites"] table. Warning: The "inchi_key" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri_type" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "" column at position 10 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values.