Validation Log 2025-12-14 21:19:28.799501 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000411/mwtab/json Study ID: ST000259 Analysis ID: AN000411 File format: json Status: Contains Validation Issues Number of Issues: 19 Number of Warnings: 10 Number of Value Errors: 17 Number of Consistency Errors: 1 Number of Format Errors: 0 Issue Log: Error: An empty value or a null value was detected in ["COLLECTION"]["COLLECTION_SUMMARY"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["TREATMENT"]["TREATMENT_SUMMARY"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["TREATMENT"]["ANIMAL_ENDP_CLINICAL_SIGNS"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["SAMPLEPREP_SUMMARY"]. A legitimate value should be provided for this required key. Error: The value, "250ºC", in ["MS"]["DRY_GAS_TEMP"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "200 ΔL/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "2 ΔL", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The following metabolites in the ["MS_METABOLITE_DATA"]["Metabolites"] table were not found in the ["MS_METABOLITE_DATA"]["Data"] table: "2'-deoxycytidine" "2'-deoxyuridine" "arginine, pos" Warning: The "ri" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "ri" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "ri_type" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "pubchem_id" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "inchi_key" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "kegg_id" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table has all null values. Warning: The "other_id" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "other_id_type" column at position 9 in the ["MS_METABOLITE_DATA"]["Metabolites"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.