Validation Log 2025-12-14 21:25:07.059179 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000484/mwtab/txt Study ID: ST000305 Analysis ID: AN000484 File format: txt Status: Contains Validation Issues Number of Issues: 21 Number of Warnings: 12 Number of Value Errors: 20 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 8 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 9 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 10 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 11 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 12 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 13 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 14 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 15 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 16 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 17 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 18 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Warning: The value, "", for the "Result Code" in "Additional sample data" in entry 19 of the "SUBJECT_SAMPLE_FACTORS" section is missing a value. Error: An empty value or a null value was detected for the subsection, "COLLECTION_SUMMARY", in the "COLLECTION" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: The value, "3299.5", for the subsection, "OFFSET_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "3.893", for the subsection, "ACQUISITION_TIME", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s']. Ignore this when more complicated descriptions are required. Error: The value, "12.0227 ppm, 8.417 Hz", for the subsection, "SPECTRAL_WIDTH", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "0.04", for the subsection, "BINNED_INCREMENT", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY".