Validation Log 2025-12-14 21:31:45.149124 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000614/mwtab/txt Study ID: None Analysis ID: None File format: txt Status: Contains Validation Issues Number of Issues: 14 Number of Warnings: 6 Number of Value Errors: 12 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "3500", for the subsection, "CAPILLARY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "325", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1000", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "Pos", for the subsection, "IONIZATION", in the "MS" section should not be "positive" or "negative". "ION_MODE" is where that should be indicated. Error: The value, "750", for the subsection, "OCTPOLE_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "3uL", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "Autosampler temp 4 C", for the subsection, "TARGET_SAMPLE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "row m/z" column at position 3 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Pubchem ID" column at position 5 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "row ID" column at position 2 in the METABOLITES table, matches a standard column name, "other_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 4 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column "row ID" was found in the METABOLITES table, but this column implies that another column, "other_id_type", should also exist, and that column was not found. Warning: The standard column, "other_id", was found in the METABOLITES table as "row ID". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column.