Validation Log 2025-12-14 21:31:55.381693 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000616/mwtab/json Study ID: ST000382 Analysis ID: AN000616 File format: json Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 2 Number of Value Errors: 12 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "3500", in ["MS"]["CAPILLARY_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "120", in ["MS"]["FRAGMENT_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V']. Ignore this when more complicated descriptions are required. Error: The value, "1000", in ["MS"]["ION_SPRAY_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "Pos", in ["MS"]["IONIZATION"] should not be "positive" or "negative". "ION_MODE" is where that should be indicated. Error: The value, "750", in ["MS"]["OCTPOLE_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V']. Ignore this when more complicated descriptions are required. Error: The value, "65", in ["MS"]["SKIMMER_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["MS"]["MS_COMMENTS"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The value, "3uL", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "Autosampler temp 4 C", in ["CHROMATOGRAPHY"]["TARGET_SAMPLE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "m/z" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RT" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Error: The ["MS_METABOLITE_DATA"]["Data"] table does not have a column for "Metabolite". It is likely misspelled or using a common incorrect substitute. Error: Column(s) with no name were found in the ["MS_METABOLITE_DATA"]["Data"] table.