Validation Log 2025-12-14 21:34:27.940555 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000629/mwtab/json Study ID: ST000393 Analysis ID: AN000629 File format: json Status: Contains Validation Issues Number of Issues: 14 Number of Warnings: 4 Number of Value Errors: 11 Number of Consistency Errors: 0 Number of Format Errors: 3 Issue Log: Error: The value, "Pos", in ["MS"]["IONIZATION"] should not be "positive" or "negative". "ION_MODE" is where that should be indicated. Error: An empty value or a null value was detected in ["MS"]["MS_COMMENTS"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The value, "1 ml/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "50-330C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "7.7 PSI", in ["CHROMATOGRAPHY"]["COLUMN_PRESSURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'bar']. Ignore this when more complicated descriptions are required. Error: The value, "230C", in ["CHROMATOGRAPHY"]["TRANSFERLINE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "30 m length x 0.25 mm internal diameter", in ["CHROMATOGRAPHY"]["SAMPLE_LOOP_SIZE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "Quantified m/z" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Pubchem ID" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG ID" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention Time" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.