Validation Log 2025-12-14 21:40:07.527199 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000691/mwtab/json Study ID: ST000440 Analysis ID: AN000691 File format: json Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 0 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: The value, "0.5mM", in ["NM"]["STANDARD_CONCENTRATION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mM']. Ignore this when more complicated descriptions are required. Error: The value, "700MHz", in ["NM"]["SPECTROMETER_FREQUENCY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['MHz']. Ignore this when more complicated descriptions are required. Error: The value, "3299", in ["NM"]["OFFSET_FREQUENCY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "298.1K", in ["NM"]["TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: The value, "3.893s", in ["NM"]["ACQUISITION_TIME"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s']. Ignore this when more complicated descriptions are required. Error: The value, "2s", in ["NM"]["RELAXATION_DELAY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s', 'ms', 'us', 'μs']. Ignore this when more complicated descriptions are required. Error: The value, "12.0277ppm", in ["NM"]["SPECTRAL_WIDTH"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "0.5Hz", in ["NM"]["LINE_BROADENING"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['Hz']. Ignore this when more complicated descriptions are required. Error: The value, "0.04ppm", in ["NM"]["BINNED_INCREMENT"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid sections, "CHROMATOGRAPHY", "Data". Error: There must be either a "NMR_METABOLITE_DATA" section, a "NMR_BINNED_DATA" section or a "NMR_RESULTS_FILE" subsection in the "NM" section. Neither were found.