Validation Log 2025-12-14 21:44:47.815239 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000745/mwtab/txt Study ID: ST000479 Analysis ID: AN000745 File format: txt Status: Contains Validation Issues Number of Issues: 5 Number of Warnings: 2 Number of Value Errors: 3 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: The value, "600MHz", for the subsection, "SPECTROMETER_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['MHz']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY". Warning: The "PubChem ID" column at position 2 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG ID" column at position 3 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Error: The NMR_METABOLITE_DATA table does not have a column for "Samples". It is likely misspelled or using a common incorrect substitute.