Validation Log 2025-12-14 21:54:03.464373 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000809/mwtab/txt Study ID: ST000530 Analysis ID: AN000809 File format: txt Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 0 Number of Value Errors: 10 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "14 weeks; drug administration since the 5th week", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "WEIGHT_OR_WEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: The value, "250 oC", for the subsection, "CAPILLARY_TEMPERATURE", in the "MS" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "400 oC", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "50 arbitary unit", for the subsection, "DESOLVATION_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "400 oC", for the subsection, "DESOLVATION_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "50 oC", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "6000-10000", for the subsection, "COLUMN_PRESSURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'bar']. Ignore this when more complicated descriptions are required. Error: The value, "4 oC", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing.