Validation Log 2025-12-14 21:55:01.697863 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000829/mwtab/txt Study ID: ST000545 Analysis ID: AN000829 File format: txt Status: Contains Validation Issues Number of Issues: 9 Number of Warnings: 0 Number of Value Errors: 8 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "Medium", for the subsection, "COLLISION_GAS", in the "MS" section should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "5500", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "0.5mL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "50 degrees C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "10uL", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "9.5 minutes", for the subsection, "ANALYTICAL_TIME", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['min']. Ignore this when more complicated descriptions are required. Error: The value, "10 degrees C", for the subsection, "TARGET_SAMPLE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "100uL", for the subsection, "SAMPLE_LOOP_SIZE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing.