Validation Log 2025-12-14 22:05:07.933363 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000911/mwtab/txt Study ID: ST000595 Analysis ID: AN000911 File format: txt Status: Contains Validation Issues Number of Issues: 10 Number of Warnings: 0 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "Urine", for the subsection, "BLOOD_SERUM_OR_PLASMA", in the "COLLECTION" section should be one of "Blood", "Plasma", or "Serum". Ignore this when more complicated descriptions are required. Error: The value, "300C", for the subsection, "CAPILLARY_TEMPERATURE", in the "MS" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "N2", for the subsection, "COLLISION_GAS", in the "MS" section should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "45", for the subsection, "DRY_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "250C", for the subsection, "DRY_GAS_TEMP", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "+3500", for the subsection, "SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['kV']. Ignore this when more complicated descriptions are required. Error: The value, "118ms", for the subsection, "ACTIVATION_TIME", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ms']. Ignore this when more complicated descriptions are required. Error: The required property, "UNITS", for the subsection, "MS_RESULTS_FILE", in the "MS" section is missing. Error: The value for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required.