Validation Log 2025-12-14 22:05:50.232660 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000926/mwtab/json Study ID: ST000605 Analysis ID: AN000926 File format: json Status: Contains Validation Issues Number of Issues: 17 Number of Warnings: 2 Number of Value Errors: 16 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected in ["PROJECT"]["PHONE"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["STUDY"]["PHONE"]. A legitimate value should be provided for this required key. Error: The value in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "Healthy - Mean (+SD): 74.4±1.71 kg; BMI < 30", in ["SUBJECT"]["WEIGHT_OR_WEIGHT_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: The value, "Healthy - Mean (±SD): 171.8±10.3cm", in ["SUBJECT"]["HEIGHT_OR_HEIGHT_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['cm', 'in']. Ignore this when more complicated descriptions are required. Error: The value in ["SUBJECT"]["GENDER"] should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: The value, "Healthy - Whole blood and Serum | Sepsis - Serum", in ["COLLECTION"]["BLOOD_SERUM_OR_PLASMA"] should be one of "Blood", "Plasma", or "Serum". Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["EXTRACT_CLEANUP"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The value, "10% (~0.5mM)", in ["NM"]["STANDARD_CONCENTRATION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mM']. Ignore this when more complicated descriptions are required. Error: The value, "around -178Hz", in ["NM"]["OFFSET_FREQUENCY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "25°C", in ["NM"]["TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: The value, "N/A", in ["NM"]["BINNED_INCREMENT"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["NM"]["BINNED_DATA_PROTOCOL_FILE"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: An empty value or a null value was detected in ["NM"]["BINNED_DATA_EXCLUDED_RANGE"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: Unknown or invalid section, "CHROMATOGRAPHY". Warning: The "KEGG ID" column at position 2 in the ["NMR_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CCMB03S" column at position 4 in the ["NMR_METABOLITE_DATA"]["Data"] table has all null values.