Validation Log 2025-12-14 22:05:54.839237 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000928/mwtab/txt Study ID: ST000607 Analysis ID: AN000928 File format: txt Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 1 Number of Value Errors: 12 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected for the subsection, "PHONE", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: The value, "10 weeks and 12-24 months (young & old)", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "~25 g and ~34 g", for the subsection, "WEIGHT_OR_WEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "COLLECTION_SUMMARY", in the "COLLECTION" section. A legitimate value should be provided for this required subsection. Error: The value, "Whole blood", for the subsection, "BLOOD_SERUM_OR_PLASMA", in the "COLLECTION" section should be one of "Blood", "Plasma", or "Serum". Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "EXTRACT_CLEANUP", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "10% (~0.5mM)", for the subsection, "STANDARD_CONCENTRATION", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mM']. Ignore this when more complicated descriptions are required. Error: The value, "around -178Hz", for the subsection, "OFFSET_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "25°C", for the subsection, "TEMPERATURE", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY". Warning: The "KEGG ID" column at position 2 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.