Validation Log 2025-12-14 22:07:22.876406 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN000957/mwtab/txt Study ID: ST000625 Analysis ID: AN000957 File format: txt Status: Contains Validation Issues Number of Issues: 12 Number of Warnings: 0 Number of Value Errors: 8 Number of Consistency Errors: 0 Number of Format Errors: 4 Issue Log: Error: An empty value or a null value was detected for the subsection, "PHONE", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "PHONE", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: The value, "4000V", for the subsection, "CAPILLARY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "10L/min", for the subsection, "DESOLVATION_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "300C", for the subsection, "DESOLVATION_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "0.3ml/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing.