Validation Log 2025-12-14 22:21:23.086338 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001243/mwtab/txt Study ID: ST000784 Analysis ID: AN001243 File format: txt Status: Contains Validation Issues Number of Issues: 9 Number of Warnings: 4 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "0.3ml/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Warning: The "Precursor Ion" column at position 4 in the METABOLITES table, matches a standard column name, "ion". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Product Ions" column at position 5 in the METABOLITES table, matches a standard column name, "ion". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Kegg ID" column at position 2 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention Time(min)" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.