Validation Log 2025-12-14 22:22:52.662850 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001274/mwtab/json Study ID: ST000802 Analysis ID: AN001274 File format: json Status: Contains Validation Issues Number of Issues: 12 Number of Warnings: 6 Number of Value Errors: 12 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: An empty value or a null value was detected in ["MS"]["MS_COMMENTS"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The value, "0.25 uL", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "5 µL", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "600 µL", in ["CHROMATOGRAPHY"]["WEAK_WASH_VOLUME"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "600 µL", in ["CHROMATOGRAPHY"]["STRONG_WASH_VOLUME"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "17 µL", in ["CHROMATOGRAPHY"]["SAMPLE_LOOP_SIZE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Warning: The "[M] neutral acc mass" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "[M-H]- resp [M+H]+ acc mass" column at position 9 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "InChI Key" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "inchi_key". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "full name" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "name". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PubChem" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Ret.Time" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.